Add comment Created on Apr 22, 2016 11:04:07 AM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down hello again, I checked the interfacenumbers and the re-added sensor has As you can see from above, other OIDs from the MIB work fine in SNMP Tester 3.2. Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • navigate here

But as soon as PRTG starts polling them, it fails, giving "No Such Name (SNMP error #2)". Test 1.3.6.1.2.1.1.1.0: value=Raven XE EV-DO # Test 1.3.6.1.2.1.1.3.0: value=130388 # Test 1.3.6.1.2.1.1.4.0: value= # Test 1.3.6.1.2.1.1.5.0: value= # Test 1.3.6.1.2.1.1.6.0: value=No response (check: firewalls, routing, snmp settings of device, IPs, SNMP This is very unusual. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • https://kb.paessler.com/en/topic/59631-no-such-instance-snmp-error-223

Nosuchinstance Snmp

This could have been caused by a device reboot or configuration change on the device. Add comment Created on Dec 19, 2013 2:53:21 PM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down When I "Get" the OID 1.3.6.1.2.1.2.2.1.8.1 using SnmpB This is what is retrieved by the SnmpB tool. 1: sysDescr.0 Raven XE EV-DO 2: sysObjectID.0 airlink.12.20 3: sysUpTimeInstance 7:18:54.22 4: sysContact.0 5: sysName.0 6: sysLocation.0 7: sysServices.0 76 8: ifNumber.0 Best Regards, Add comment Created on Jul 13, 2016 12:27:31 PM by Luciano Lingnau [Paessler Support] Last change on Jul 13, 2016 12:27:54 PM by Luciano Lingnau [Paessler Support] Permalink Votes:0

  • You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy •
  • Add comment Created on Jul 25, 2016 6:30:30 AM by Stephan Linke [Paessler Support] Permalink Votes:0 Your Vote: Up Down Hi Stephan - yes.
  • I don't believe there are any ACLs between devices on the same subnet - and even if there were, is it possible for it to restrict what OIDs could be polled?
  • I can get a result using snmpwalk from CLI snmpwalk -c public -v 2c x.x.x.x 1.3.6.1.2.1 DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (25303833) 2 days, 22:17:18.33 However, if I create a new probe with
  • Add comment Created on Apr 18, 2012 3:49:05 PM by helixstorm (0) ●1 Permalink Accepted Answer Votes:0 Your Vote: Up Down What precise OID are you using?
  • This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general.
  • Howerver when rebooting the OS, most of the time the Sensor goes in "No Such Instance SNMP error # 223".
  • Find out how you can reduce cost, increase QoS and ease planning, as well.
  • Please see what happens, if you remove it and perform the walk again.

Learn more Top Tags 5804× prtg 1858× snmp 1476× sensor 948× wmi 628× notifications 478× maps View all Tags No such instance (SNMP error #223) Votes:0 Your Vote: Up Down This looks like a bug in the SNMP agent. Please put them between { { { and } } } to improve readability (without the whitespaces between). Snmp Error Codes Please make sure it is 1.3.6.1.4.1.232.22.2.3.1.1.1.5.1.

Are you able to access the OID using a different program using a get request (e.g. Prtg Snmp Error # -2003 Alternatively you can download the software from our Paessler Service Center using your registered email and password. The OID I am polling is 1.3.6.1.2.1.1.5 for sysName. https://kb.paessler.com/en/topic/61528-no-such-instance-snmp-error-223 Find out how you can reduce cost, increase QoS and ease planning, as well.

Use at your own risk. Snmp No Such Object For the current already "broken" sensors, you can manually edit the interface number field (just use the new sensors and copy it from them), to get them working again. Thanks! I have been trying to add a standard SNMP sensor to monitor bandwidth usage etc.

Prtg Snmp Error # -2003

Tested it so far with one sensor and it seems to work fine. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • Nosuchinstance Snmp best regards. Prtg Snmperr_no_vars I will test it now on the other switchports and give feedback, if it works or not. :) best regards Fraggles Add comment Created on Apr 22, 2016 10:29:32 AM by

That's definitively very strange, can't say I've seen much similar cases until now. check over here This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. Does that work? Once you have downloaded the latest version, you can install it directly over the version currently running. Snmpget No Such Instance Currently Exists At This Oid

Best regards, Sven dell poweredge snmp Created on Jun 9, 2016 8:35:32 AM by SvenVR73 (0) ●1 Permalink 8 Replies Votes:0 Your Vote: Up Down Hello Sven, Since you use an Will keep you informed if this solves the problem. When I conduct a Walk on 1.3.6.1.4.1.9.9.473.1.3.6.1.4 for either a host that is in error or not I get the proper response: Paessler SNMP Tester 5.2.3 Computername: PRTGPROBENWAE01 Interface: (10.76.224.84) 6/17/2016 his comment is here But if I switch to SNMPv1, I can get the available interfaces, and I can read the 32-bit counters OK.

Add comment Created on Dec 16, 2013 4:08:28 PM by NextNav (0) ●1 Last change on Sep 23, 2015 4:50:42 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up Snmp Tester It is the ESX host itself that I am trying to monitor. Cheers Mal Add comment Created on Jul 25, 2016 10:59:55 PM by malevans (0) ●1 Permalink Votes:0 Your Vote: Up Down This indicates that the device doesn't expose all optional channels.

I have a problem with SNMPv2 traffic sensors on interfaces of a VMware server.

Before applying any instructions please exercise proper system administrator housekeeping. Free PRTG Download >> What is this? You are invited to get involved by asking and answering questions! This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general.

Enable them one by one to see which one causes the error. This would be expected for instance when a disk is replaced. If your device's indexes are changing during regular operation this could be a firmware/software issue in the SNMP Implementation, those indexes shouldn't change randomly. weblink There may be one or more PIM entries associated with a single peripheral gateway entry.