Please check on the same with the vendor in case. Are you polling from the same IP / management range ? Add comment Created on Dec 17, 2013 1:22:21 PM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down Walk using SNMP Tester 5.1 ----------------------- New Test Add comment Created on Oct 26, 2010 2:37:05 PM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down Is there any access-list active on the switch / device? navigate here

I have a problem with SNMPv2 traffic sensors on interfaces of a VMware server. This could have been caused by a device reboot or configuration change on the device. This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. Not quite, we have all of our APs set to fail over between our Austin office and the New York office controllers, whenever an AP fails over or gets disconnected for

Nosuchinstance Snmp

Best Regards, Luciano Lingnau [Paessler Support] Add comment Created on Jun 20, 2016 10:41:37 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up Down Thanks Luciano, I have updated The failure code is "Value: No such instance (SNMP error # 223)". I add new sensor : SNMP Disk Free After some time i see : No such instance (SNMP error # 223) Can you provide me the info about it? Add comment Created on Sep 22, 2014 3:44:51 PM by kkunzler (0) ●1 Permalink Votes:0 Your Vote: Up Down Could you please forward us the results of both tests, including detailed

  1. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy •
  2. This indexing method ensures that PIM entries are properly related to its parent peripheral gateway and to the appropriate instance.
  3. One of the basic tests I am doing is to check if SNMP polling is working from the PRTG station.
  4. Before applying any instructions please exercise proper system administrator housekeeping.
  5. I got myself the lab guide from Microsoft and a capable server.
  6. Add comment Created on Jun 20, 2016 6:41:46 PM by mtknepper (0) ●1 Last change on Jun 21, 2016 9:17:31 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up

Any idea why I am not able to pull this OID from PRTG or from SNMPTester when snmp walk from CLI works fine? You can set PRTG to try catch such changes in the future and adjust the sensors accordingly, so that they continue to work: Automatically update port name and number for SNMP Please refer to this thread in order to understand where the query stems from. Snmp Error Codes Learn more Top Tags 5804× prtg 1858× snmp 1476× sensor 948× wmi 628× notifications 478× maps View all Tags No such instance (SNMP error 223) after reboot of Windows server

Add comment Created on Apr 25, 2016 8:03:30 AM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down Perfect! Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. After re-adding the sensors work fine again. check that This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general.

You might want to contact dell to discuss your case. Snmp No Such Object This means that the data contained in the SNMP Agent of the device was "re-ordered" and PRTG is no longer able to identify the data it was originally monitoring. Add comment Created on Dec 16, 2013 9:54:59 AM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down This is what I get when I try Deleting the sensor and recreating the sensor solves the problem.

Prtg Snmp Error # -2003

For the current already "broken" sensors, you can manually edit the interface number field (just use the new sensors and copy it from them), to get them working again. https://kb.paessler.com/en/topic/70048-no-such-instance-snmp-error-223-after-reboot-of-windows-server I will test it now on the other switchports and give feedback, if it works or not. :) best regards Fraggles Add comment Created on Apr 22, 2016 10:29:32 AM by Nosuchinstance Snmp The message No such instance is the reply of the device when PRTG asks for the OID that it was monitoring until now and the device tells PRTG that "this 'address' Prtg Snmperr_no_vars greetings Fraggles prtg snmp snmp-error#223 Created on Apr 22, 2016 8:00:38 AM by Fraggles (0) ●1 Permalink Best Answer Accepted Answer Votes:0 Your Vote: Up Down It seems that the interface

You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • check over here You are invited to get involved by asking and answering questions! As you can see from above, other OIDs from the MIB work fine in SNMP Tester 3.2. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • Snmpget No Such Instance Currently Exists At This Oid

My question is this, how to I get it to input the name of the AP in the notification instead of No Such Instance in the notification? And in PRTG both the library scan and the individual OIDs work (with SNMP Custom Sensors)? Will keep you informed if this solves the problem. his comment is here Add comment Created on Dec 14, 2011 3:13:38 PM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down I'm afraid I'm seeing this same issue, except that it works

Help Desk » Inventory » Monitor » Community » Snmp Tester Enter Pertino, giving us local-like access from remote offices without the MPLS or IPSec VPN costs! Add comment Created on May 6, 2013 1:22:52 PM by Aurelio Lombardi [Paessler Support] Permalink Please log in or register to enter your reply.

With the PRTG tester, scanning the available interfaces, it seems to find them OK: Found standard interfaces: 1:06:00.0: (001) 06:00.0,Connected,1 GBit/s,Ethernet,06:00.0, 64 Bit 2:08:00.0: (002) 08:00.0,Connected,1 GBit/s,Ethernet,08:00.0, 64 Bit etc.

This is very unusual. You are invited to get involved by asking and answering questions! Its just annoying in the error overview to have all these ports (also on some other switches) shown up. Learn more Top Tags 5804× prtg 1858× snmp 1476× sensor 948× wmi 628× notifications 478× maps View all Tags Trouble with SNMP traffic sensors Votes:0 Your Vote: Up Down This

But after I create sensors on the actiove ones, they all go red ("Show alarm when disconnected") once PRTG starts trying to read the counters. The No such instance (SNMP error 223) message is directly related to changing SNMP Indexes. Does that work? weblink Please contact us via a support ticket, this will allow us to troubleshoot the actual data expected by the sensor and returned by your iDrac's to check out what's causing the

Could you maybe help me with this issue? Yet a Spectrum SNMPv2c walk tells me that the 64-bit counters are all present and correct. I have this problem on several Dell PowerEdge Servers (all R730 family) Add comment Created on Jul 13, 2016 11:21:31 AM by SvenVR73 (0) ●1 Last change on Jul 13, 2016 our ESX hosts are still on 5.1.0, 914609 I will update one today to check if that makes a difference.

Before this date they also were scanned without any issues. Add comment Created on Apr 22, 2016 12:38:39 PM by Fraggles (0) ●1 Permalink Accepted Answer Votes:0 Your Vote: Up Down It seems that the interface numbers did change. But as soon as PRTG starts polling them, it fails, giving "No Such Name (SNMP error #2)". I create the sensors manualy.

You are invited to get involved by asking and answering questions! Great right? Add comment Created on Apr 22, 2016 11:04:07 AM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down hello again, I checked the interfacenumbers and the re-added sensor has Add comment Created on Sep 22, 2014 3:35:12 PM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down As mentioned in the original post, doing a

The OID I am polling is 1.3.6.1.2.1.1.5 for sysName. Before applying any instructions please exercise proper system administrator housekeeping. Free PRTG Download >> What is this? For the current already "broken" sensors, you can manually edit the interface number field (just use the new sensors and copy it from them), to get them working again.

When I remove the sensor and add it the problem is gone for a couple of days. Find out how you can reduce cost, increase QoS and ease planning, as well. Please feel free to share the outcome of your contact with Cisco, I expect them to acknowledge this as a bug(or blame Microsoft's SNMP Agent implementation). Add comment Created on Jul 14, 2016 6:30:03 AM by SvenVR73 (0) ●1 Permalink Votes:0 Your Vote: Up Down Hello, We have the same issue with this sensor on two of

Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Please make sure it is 1.3.6.1.4.1.232.22.2.3.1.1.1.5.1. SNMP works properly on about 150 switchports, but around 20 ports cant be monitored since the 29th of march. Instead of running a "Scan OIDLIB" test, could you please run a "Walk" using the base OID 1.3.6.1.2.1.2?